Watertube Boiler
Brand : CLEVER BROOKS
Last Update : 11:22:18 03/03/2011
ClearFire-H The New standard in Commercial High-efficiency Firetube Boilers
Brand : CLEVER BROOKS
Last Update : 11:19:47 03/03/2011
ClearFire-V Commercial Steam Boiler / High-efficiency ,Compact
Brand : CLEVER BROOKS
Last Update : 11:17:20 03/03/2011

Page View  9222  
Product Information :

Product Name:  
ClearFire-V Commercial Steam Boiler / High-efficiency ,Compact


Product Category:   ผลิตภัณฑ์เครื่องทำความร้อน, ความเย็น, อุณหภูมิ
Product Sub-Category:   หม้อไอน้ำ
Brand:   CLEVER BROOKS  
Product Type :   สินค้า, ผลิตภัณฑ์ 
     
 




CLEARFIRE-V Features
•Vertical design for small fooprint
• High efficiencies up to 85%, reduces greenhouse gas emissions
•Maximize fuel saving with full burner modulation
and high-turndown via variable Speed Blower
• Easily-tuned, zero-governor, premix burner
• More reliable operation with no dampers or linkages
• Advanced combustion design eliminates need for
flue gas recirculation and provides low emissions
(<20 ppm NOx and < 10 ppm CO)
• ModBus (RS 485) communications
• Direct Spark Ignition
• Low Gas Pressure < 14” W.C.
• Ultra quiet operation < 70 DBA
• Single Phase Power 115V - minimal electrical energy consumption
• UL Listed (Natural Gas)
• Controls are CSD-1 Compliant



Advenced Burner Technology

The ClearFire-V's high efficiency is achieved by employing an
advanced Fecralloy burner designedto premix air and fuel for
optimal combustion and low emissions. A varible speed blower motor
provides extended burner turndown capabilty


Patented Heat Tranfer Technology®

The internationally patented Alufer firetube is the latest Claver-Brooks
innovation in advanced heat transfer technology.
The tube is constructed from an inner aluminum alloy finned surface,
die fitted within an outer carbon steel tube providing exceptional
heat exchange characteristics that are attributed to the following factors:
• Thermal conductivity of the Alufer insert is significantly greater than
that of carbon steel.
• internal finned surface of the Alufer® tube enlarges the heat exchange
surface area threefold
• Inner surface of the tube is divided into ten flow channels
to create maximum turbulence and heat transfer.




Durable Fecralloy Burner



Patented AluFer Tubes®
Clearfire-V Boiler Dimensions and Ratings
Boiler H.P.
10 15 20 25 30 40 50 60
Dimentions - INCHES
Overall Length (A)
50
50
55
55
68
68
75
75
Overall Width (B)
32
32
39
39
47
47
56
56
Overall Hight (C)
73
77
73
79
72
78
81
87
Overall Hight (CC)
84
90
84
90
86.5
92.5
99
6
Stack Nominal OD (D)
6
6
6
6
8
8
10
10
Steam Boiler Weights in LBS
Normal Water Weight - 150#
710
815
1,195
1,365
1,795
2,050
2,715
3,090
Approx. Shipping Weight
2,000
2,120
2,540
2,780
3,690
4,030
5,280
5,740
Power Requirements (Single Phase, 115 or 230 VAC)
Blower Motor Size (Watts)*
335
335
335
335
335
750
1,200
1,200
Ratings
Rated Capacity - Steam
(lbs-steam/hr from & at 212° F)
345
518
690
837
1,035
1,380
1,725
2,070
Output (1,000 Btu/hr)
338
506
665
837
1,014
1,355
1,662
2,011
Input (1,000 Btu/hr)
398
598
797
996
1,195
1,594
1,992
2,391
Firesidw Heating Surface (sq.ft.)
84
103
128
159
208
258
312
388
Efficency %
84.9
84.6
83.5
84
84.8
85
83.4
84.1
Turndown/Modulating Firing Rate
4:1
4:1
4:1
4:1
4:1
5:1
5:1
5:1
Notes:
* For alttiudes above 1500 ft.,contact local Claver-Brooks authorized representative for verification of boiler and blower motor size.
** All Ratings from 0 psig and at 212°
 

© 2000-2008 CopyRight by BOONYIUM & ASSOCIATES LIMITED
Tel. 02-322-1678-87 , 02-322-4330-3
disclaimer | privacy | contact us 

  Sale Login Warehouse Login Driver Login