Environmental ConditionsSpecifications range-20?C to +60?CCalibration temperature20...28?CRelative humidity< 95% RH (non-cond.)Protection degreeIP20Mechanical specificationsDimensions (HxWxD)109 x 23.5 x 104 mmDimensions (HxWxD) w/ 4501 / 4511109 x 23.5 x 116 / 131 mmWeight approx.145 gWeight incl. 4501 / 4511 (approx.)160 g / 245 gWire size1 x 2.5 mm2 stranded wireScrew terminal torque0.5 NmVibration: 2...13.2 Hz?1 mmVibration: 13.2...100 Hz?0.7 gCommon specificationsSupply voltage, universal21.6...253 VAC, 50...60 Hz or 19.2...300 VDCFuse400 mA SB / 250 VACMax. power consumption? 2.0 WIsolation voltage, test / working2.3 kVAC / 250 VACCommunications interfaceCommunication enabler 4511 / Programming front 4501Signal / noise ratioMin. 60 dB (0...100 kHz)Response time (0...90%, 100...10%): Temperature input? 1 sResponse time (0...90%, 100...10%): mA / V input? 400 msAuxiliary supplies: 2-wire supply (terminal 44...43)25...16 VDC / 0...20 mAAccuracyBetter than 0.1% of selected rangeEMC immunity influence< ?0.5% of spanExtended EMC immunity: NAMUR NE 21, A criterion, burst< ?1% of spanInput specificationsRTD inputPt10, Pt20, Pt50, Pt100, Pt200, Pt250, Pt300, Pt400, Pt500, Pt1000 Ni50, Ni100, Ni120, Ni1000, Cu10, Cu20, Cu50, Cu100 Linear resistance Potentiometer Cable resistance per wire (max.), RTD50 ?Sensor current, RTDNom. 0.2 mAEffect of sensor cable resistance (3-/4-wire), RTD< 0.002 ? / ?Sensor error detection, RTDYesShort circuit detection, RTD< 15 ?TC input: Thermocouple typeB, E, J, K, L, N, R, S, T, U, W3, W5, LRCold junction compensation (CJC) via ext. sensor in connector 591020...28?C ? ?1?C, -20...20?C / 28...70?C ? 2?CCJC via internally mounted sensor?(2.0?C + 0.4?C * ?t)?t =Internal temperature-ambient temperatureSensor error detection, TCYesSensor error current: When detecting / elseNom. 2 ?A / 0 ?ACurrent input: Measurement range0...20 mACurrent input: Programmable measurement ranges0...20 and 4...20 mAInput resistance, current inputNom. 20 ? + PTC 50 ?Voltage input: Measurement range0...12 VDCProgrammable measurement ranges, VDC0/0.2...1, 0/1...5, 0/2...10 VDCInput resistance, voltage inputNom. 10 M?Output specificationsCurrent output: Signal range0...20 mAProgrammable current ranges0...20 / 4...20 / 20...0 and 20...4 mALoad (max.)20 mA/800 ?/16 VDCLoad stability, current output?0.01% of span / 100 ?Sensor error indication, current output0 / 3.5 / 23 mA / noneNAMUR NE 43 Upscale/Downscale23 mA / 3.5 mACurrent limit? 28 mAVoltage output: signal range0...10 VDCProgrammable voltage ranges0/0.2...1; 0/1...5 ; 0/2...10; 1...0.2/0; 5...1/0; 10...2/0 VLoad (min.)500 k?*of span= of the currently selected measurement rangeApprovalsEMCEN 61326-1LVD 2006/95/ECEN 61010-1FM3025177ULUL 508EAC TR-CU 020/2011EN 61326-1DNV MarineStand. f. Certific. No. 2.4SILHardware assessed for use in SIL applications
|